Line 38: Line 38:
 | 0    | ?? | | 0    | ?? |
 | 1    | Timer enable | | 1    | Timer enable |
-| 2    | ?? |+| 2    | Count direction; 0=up, 1=down |
 | 4-6  | Prescaler | | 4-6  | Prescaler |
  
Line 59: Line 59:
 **0xF0000414** **0xF0000414**
  
-Counter. Can be written to, the timer will count from the new value.+Counter. Can be written to, the timer will count from the new value. Writes are ignored when the timer isn't active.
  
-When the timer goes past the target, the timer is reloaded to 0 and IRQ 0x00 is triggered.+When the timer goes past the target in count-up mode, or below zero in count-down mode, the timer is reloaded (to 0 in count-up mode, to the target value in count-down mode) and IRQ 0x00 is triggered.
  
 Writing a new value greater than the target does not cause a reload. Writing a new value greater than the target does not cause a reload.
Line 72: Line 72:
 Target. Target.
  
-Before a reload, the last value the timer takes is equal to the target.+In count-up mode, before a reload, the last value the timer takes is equal to the target. It is then reloaded to 0. 
 + 
 +In count-down mode, before a reload, the last value the timer takes is 0. It is then reloaded to the target value.
  
  